Mostrar el registro sencillo del ítem

dc.contributor.authorVan Haute, S
dc.contributor.authorErickson, M
dc.contributor.authorDevlieghere, F
dc.contributor.authorAllende, A
dc.contributor.authorSampers, I
dc.contributor.authorLópez Gálvez, F.
dc.date.accessioned2017-07-24T12:30:19Z
dc.date.available2017-07-24T12:30:19Z
dc.date.issued2015
dc.identifier.citation4es
dc.identifier.isbn01681605
dc.identifier.urihttp://hdl.handle.net/10952/2397
dc.description.abstractA methodology to i) assess the feasibility of water disinfection in fresh-cut leafy greens wash water and ii) to compare the disinfectant efficiency of water disinfectants was defined and applied for a combination of peracetic acid (PAA) and lactic acid (LA) and comparison with free chlorine was made. Standardized process water, a watery suspension of iceberg lettuce, was used for the experiments. First, the combination of PAA + LA was evaluated for water recycling. In this case disinfectant was added to standardized process water inoculated with Escherichia coli (E. coli) O157 (6 log CFU/mL). Regression models were constructed based on the batch inactivation data and validated in industrial process water obtained from fresh-cut leafy green processing plants. The UV254(F) was the best indicator for PAA decay and as such for the E. coli O157 inactivation with PAA + LA. The disinfection efficiency of PAA + LA increased with decreasing pH. Furthermore, PAA + LA efficacy was assessed as a process water disinfectant to be used within the washing tank, using a dynamic washing process with continuous influx of E. coli O157 and organic matter in the washing tank. The process water contamination in the dynamic process was adequately estimated by the developed model that assumed that knowledge of the disinfectant residual was sufficient to estimate the microbial contamination, regardless the physicochemical load. Based on the obtained results, PAA + LA seems to be better suited than chlorine for disinfecting process wash water with a high organic load but a higher disinfectant residual is necessary due to the slower E. coli O157 inactivation kinetics when compared to chlorine.es
dc.language.isoenes
dc.publisherElsevier Ltdes
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectFresh producees
dc.subjectPeracetic acid
dc.subjectLeafy vegetables
dc.subjectE. coli O157
dc.subjectWater disinfection
dc.titleMethodology for modeling the disinfection efficiency of fresh-cut leafy vegetables wash water applied on peracetic acid combined with lactic acides
dc.typearticlees
dc.rights.accessRightsopenAccesses
dc.journal.titleInternational Journal of Food Microbiologyes
dc.volume.number208es
dc.issue.number102-113es
dc.description.disciplineCiencias de la Alimentaciónes


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como Attribution-NonCommercial-NoDerivatives 4.0 Internacional