Reliability and reproducibility of a morpho-textural image analysis method over a patellar ligament ultrasonography

dc.contributor.authorRíos Díaz, José
dc.contributor.otherGroot Ferrando, Ana
dc.contributor.otherMartínez Payá, Jacinto Javier
dc.contributor.otherBaño Aledo, María Elena
dc.date.accessioned2017-05-05T09:41:36Z
dc.date.available2017-05-05T09:41:36Z
dc.date.issued2010-05-13
dc.description.abstractOBJECTIVE: Image analysis techniques over ultrasonograms may be useful to extract quantitative information. Because ecography and the selection of the area of interest are technician-dependent, the objective of this work was to calculate the reliability and the reproducibility of the analysis method. MATERIAL AND METHODS: Test-retest reliability study on 60 cross-sectional patellar ligament ultrasonograms on 1cm of patella were carried out. Sonosite Titan L-38 (5-10 MHz) and the Image analysis software J v1.40 were used. Morphometric variables were: perimeter, area, width, thickness, and mean echogenity; textural variables were: uniformity, homogeneity and entropy. The intraclass correlation coefficient (ICC) was calculated with a confidence interval of 95%. RESULTS: Intraclass correlation coefficients over 0.70 were found, with an agreement ranging from good to very good in all of the variables both for the intra ecography and inter ecography studies. CONCLUSION: Very good levels of reliability and internal consistency were seen, demonstrating that from the statistical point of view, the variability introduced by the technician is not significant. This method can be taken as a reference to analyze the reliability between several ultrasonographers.es
dc.description.disciplineActividad Física y Deportees
dc.description.disciplineMedicinaes
dc.description.disciplineTerapia y Rehabilitaciónes
dc.identifier.citationdoi: 10.1016/j.reuma.2010.01.008es
dc.identifier.issn1699-258X
dc.identifier.urihttp://hdl.handle.net/10952/2285
dc.issue.number6es
dc.journal.titleReumatología clínicaes
dc.language.isoeses
dc.publisherElsevieres
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.accessRightsopen accesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectReliabilityes
dc.subjectUltrasonographyes
dc.subjectPatellar ligamentes
dc.subjectTextural analysises
dc.subjectComputer-assisted image processinges
dc.titleReliability and reproducibility of a morpho-textural image analysis method over a patellar ligament ultrasonographyes
dc.typejournal articlees
dc.volume.number6es
dspace.entity.typePublication

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
(Ríos-Díaz J). Reliability and reproducibility of a morpho-textural image..pdf
Size:
106.47 KB
Format:
Adobe Portable Document Format
Description:

Collections