Wearable 3D-Printed Microneedle Sensor for Intradermal Temperature Monitoring

dc.contributor.authorQikun, Wei
dc.contributor.authorRojas, Daniel
dc.contributor.authorWang, Qianyu
dc.contributor.authorZapata Pérez, Rubén
dc.contributor.authorXuan, Xing
dc.contributor.authorMolinero Fernández, Águeda
dc.contributor.authorCrespo, Gastón A.
dc.contributor.authorCuartero, María
dc.date.accessioned2026-10-05T08:06:29Z
dc.date.available2026-10-05T08:06:29Z
dc.date.issued2025-06-27
dc.description.abstractAccurate temperature monitoring plays a crucial role in understanding the physiological status of patients and the early diagnosis of diseases commonly associated with local and global infections. Intradermal temperature measurement is, in principle, more precise than skin surface detection, as it prevents interference from environmental temperature changes and skin secretions. However, to date, precise and reliable intradermal temperature monitoring in a real-time and continuous manner remains a challenge. We propose herein high-resolution 3D printing to fabricate a mechanically robust and biocompatible hollow microneedle, filled with a temperature-responsive conducting polymer (poly­(3,4-ethylenedioxythiophene): polystyrenesulfonate, PEDOT:PSS) to develop a microneedle temperature sensor (T-MN). The significance is 2-fold: rational design of robust MNs with high resolution in the micrometer domain and the implementation of a conducting polymer in a MN format for temperature sensing. The analytical performance of the developed T-MN is in vitro evaluated under mimicked intradermal conditions, demonstrating good sensitivity (−0.74%° C–1), resolution (0.2 °C), repeatability (RSD = 2%), reproducibility (RSD = 2%), reversibility, and medium-term stability. On-body temperature monitoring is performed on six euthanized rats for 80 min. The results presented good agreement with those obtained using a commercial optical temperature probe, which was intradermally inserted into the rat skin. The reliability of utilizing the T-MN for precise and continuous intradermal temperature monitoring was successfully demonstrated, noting its potential use for patient monitoring in the near future but also temperature compensation for MN (bio)­sensors that may need it.es
dc.description.disciplineFarmaciaes
dc.description.facultyUCAMSENSes
dc.identifier.citationWei, Q., Rojas, D., Wang, Q., Zapata-Pérez, R., Xuan, X., Molinero-Fernández, Á., Crespo, G. A., & Cuartero, M. (2025). Wearable 3d-printed microneedle sensor for intradermal temperature monitoring. ACS Sensors, 10(6), 4027-4037. https://doi.org/10.1021/acssensors.4c03681es
dc.identifier.doi10.1021/acssensors.4c03681es
dc.identifier.essn2379-3694
dc.identifier.urihttp://hdl.handle.net/10952/11225
dc.issue.number6es
dc.journal.titleWearable Sensorses
dc.language.isoenes
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.accessRightsopen accesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subject3D printinges
dc.subjectMicroneedlees
dc.subjectInterstitial fluides
dc.subjectTemperature monitoringes
dc.subjectConducting polymerses
dc.titleWearable 3D-Printed Microneedle Sensor for Intradermal Temperature Monitoringes
dc.typejournal articlees
dc.type.hasVersionAMes
dc.volume.number10es
dspace.entity.typePublication
person.affiliation.nameUniversidad Católica San Antonio de Murcia
person.affiliation.nameUniversidad Católica San Antonio de Murcia
person.affiliation.nameUniversidad Católica San Antonio de Murcia
person.identifier.orcid0000-0003-4432-9652
relation.isAuthorOfPublication4c49b708-f2b3-4673-a8da-a573064712e9
relation.isAuthorOfPublication9d1d7910-b9f2-4fb2-8f57-e29f235cc9c1
relation.isAuthorOfPublicationfb679c4a-dcd6-4ac6-8260-2d2cc0674fa7
relation.isAuthorOfPublication.latestForDiscovery4c49b708-f2b3-4673-a8da-a573064712e9

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
se4c03681.pdf
Size:
4.79 MB
Format:
Adobe Portable Document Format
Description:

Collections