Electromyographic comparison of traditional fitness machines, outdoor fitness equipment without load selectors, and outdoor fitness equipment with load selectors in a seated chest press exercise in trained young men

dc.contributor.authorAbelleira Lamela, Tomás
dc.contributor.authorMarcos Pardo, Pablo Jorge
dc.contributor.authorAbraldes Valeiras, José Arturo
dc.contributor.authorGonzález Gálvez, Noelia
dc.contributor.authorEspeso García, Alejandro
dc.contributor.authorEsparza Ros, Francisco
dc.contributor.authorVaquero Cristóbal, Raquel
dc.date.accessioned2025-05-30T12:17:45Z
dc.date.available2025-05-30T12:17:45Z
dc.date.issued2024
dc.description.abstractOutdoor fitness equipment (OFE) are strength training installations comparable to those found in indoor gyms but are located outdoors with greater accessibility. However, the scientific evidence supporting their effectiveness remains limited. The objective of this study was to analyze and compare the electromyographic (EMG) activity of upper limb muscle groups during the use of a traditional seated chest press (SCP) machine, a classic OFE SCP (OFE-SCP), and a new OFESCP featuring a load selector system (BIOFIT-SCP). The sample was composed of 34 active young men. EMG activity of five muscle groups was analyzed: the anterior deltoid (AD), the clavicular (CP) and sternal (SP) heads of the pectoralis major, and the lateral (LHTB) and long heads of the triceps brachii (LongHTB), under different intensities. The OFE-SCP showed significantly lower EMG activity compared with the SCP and BIOFIT-SCP in all muscles and phases (p < 0.001). Significantly lower EMG activity for the SP in all three phases was found on the BIOFIT-SCP compared with the SCP (p < 0.001), but it was significantly higher for the LHTB and AD in the BIOFIT-SCP compared with the SCP during the full and concentric phases (p < 0.05 to p < 0.001). In conclusion, training with the OFE-SCP generates less EMG activity than traditional machine training, while, in general, BIOFIT-SCP proved effective for strength training comparable to the SCP.es
dc.description.disciplineActividad Física y Deportees
dc.description.facultyDeportees
dc.identifier.citationAbelleira-Lamela, T., Marcos-Pardo, P. J., Abraldes, J. A., González-Gálvez, N., Espeso-García, A., Esparza-Ros, F., & Vaquero-Cristóbal, R. (2024). Electromyographic comparison of traditional fitness machines, outdoor fitness equipment without load selectors, and outdoor fitness equipment with load selectors in a seated chest press exercise in trained young men. Sensors (Basel, Switzerland), 24(23). https://doi.org/10.3390/s24237740es
dc.identifier.doi10.3390/s24237740es
dc.identifier.urihttp://hdl.handle.net/10952/9650
dc.issue.number23es
dc.journal.titleSensors (Basel, Switzerland)es
dc.language.isoenes
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.accessRightsopen accesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectOutdoor gymes
dc.subjectPectoralis majores
dc.subjectResistance traininges
dc.subjectSelectorized stack machinees
dc.subjectSurface EMGes
dc.subjectUpper limb musclees
dc.titleElectromyographic comparison of traditional fitness machines, outdoor fitness equipment without load selectors, and outdoor fitness equipment with load selectors in a seated chest press exercise in trained young menes
dc.typejournal articlees
dc.volume.number24es
dspace.entity.typePublication
person.affiliation.nameUniversidad Católica San Antonio de Murcia
person.affiliation.nameUniversidad Católica San Antonio de Murcia
person.affiliation.nameUniversidad Católica San Antonio de Murcia
person.affiliation.nameUniversidad Católica San Antonio de Murcia
person.affiliation.nameUniversidad Católica San Antonio de Murcia
person.affiliation.nameUniversidad Católica San Antonio de Murcia
person.identifier.orcid0000-0001-9582-208X
person.identifier.orcid0000-0003-1624-5013
person.identifier.orcid0000-0002-7291-3306
person.identifier.orcid0000-0002-5826-4821
person.identifier.orcid0000-0002-4519-1635
person.identifier.orcid0000-0003-2708-4817
relation.isAuthorOfPublication1d863f55-58d1-4875-ac08-9297267910c5
relation.isAuthorOfPublication091e5ae2-61b6-459e-afde-2a836f0c0948
relation.isAuthorOfPublicationb3b78fc7-4b37-473b-9def-5f546a650b56
relation.isAuthorOfPublicationa9bdd6eb-f765-4629-a91f-5dfce8205d48
relation.isAuthorOfPublicationac437a32-64c8-40d1-8bfc-4a98279a31fc
relation.isAuthorOfPublicationda0bb629-c120-4b55-b7c2-ce65e235fadd
relation.isAuthorOfPublication.latestForDiscovery1d863f55-58d1-4875-ac08-9297267910c5

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
4.pdf
Size:
1.95 MB
Format:
Adobe Portable Document Format
Description:
Artículo principal

Collections