Demonstration of a Validated Direct Current Wearable Device for Monitoring Sweat Rate in Sports

Loading...
Thumbnail Image

Publication date

2024-11-13

Contributors

Advisors

Journal Title

Journal ISSN

Volume Title

Publisher

Metrics

relationships.isProjectOf

relationships.isOrgUnitOf

relationships.isJournalIssueOf

Abstract

Sweat rate magnitude is a desired outcome for any wearable sensing patch dedicated to sweat analysis. Indeed, sweat rate values can be used two-fold: self-diagnosis of dehydration and correction/normalization of other physiological metrics, such as Borg scale, VO2, and different chemical species concentrations. Herein, a reliable sweat rate belt device for sweat rate monitoring was developed. The device measures sweat rates in the range from 1.0 to 5.0 µL min−1 (2 to 10 µL min−1 cm−2), which covers typical values for humans. The working mechanism is based on a new direct current (DC) step protocol activating a series of differential resistance measurements (spatially separated by 800 µm) that is gradually initiated by the action of sweat, which flows along a customized microfluidic track (~600 µm in width, 10 mm in length, and 235 µm in thickness). The device has a volumetric capacity of ~16 µL and an acquisition frequency between 0.010 and 0.043 Hz within the measured sweat rate range. Importantly, instead of using a typical and rather complex AC signal interrogation and acquisition, we put forward the DC approach, offering several benefits, such as simplified circuit design for easier fabrication and lower costs, as well as reduced power consumption and suitability for wearable applications. For the validation, either the commercial sweat collector (colorimetric) or the developed device was performed. In five on-body tests, an acceptable variation of ca. 10% was obtained. Overall, this study demonstrates the potential of the DC-based device for the monitoring of sweat rate and also its potential for implementation in any wearable sweat platform.

Description

Disciplines

Bibliographic citation

Xuan, X.; Rojas, D.; Lozano, I.M.D.; Cuartero, M.; Crespo, G.A. Demonstration of a Validated Direct Current Wearable Device for Monitoring Sweat Rate in Sports. Sensors 2024, 24, 7243. https:// doi.org/10.3390/s24227243

Collections

Endorsement

Review

Supplemented By

Referenced By

Creative Commons license

Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivatives 4.0 Internacional