Test-Retest Reliability and Convergent Validity of Piezoelectric Force Plate Measures of Single-Leg Sit-to-Stand Performance in Trained Adults

dc.contributor.authorMakaraci, Yücel
dc.contributor.authorNas, Kazim
dc.contributor.authorGündüz, Kerem
dc.contributor.authorAydemir, Mustafa
dc.contributor.authorOrange, Samuel T
dc.contributor.authorRuiz Cárdenas, Juan Diego
dc.date.accessioned2024-07-22T10:10:34Z
dc.date.available2024-07-22T10:10:34Z
dc.date.issued2023
dc.description.abstractThe single-leg sit-to-stand (STS) test has emerged as a promising method of assessing lower-limb functional strength and asymmetry. However, the reliability of its performance parameters on a force plate has not been explored. This study examined the test-retest reliability and convergent validity of the single-leg STS test performed on a piezoelectric-based force plate in trained subjects. Thirty trained male adults (age: 21.4 ± 1.7 years) performed 3 separate single-leg STS days of testing to assess both intraday and interday reliability. Performance parameters included STS time, ground reaction force (GRF), and center of pressure (CoP) sway velocity. The relationship between single-leg STS parameters and unilateral countermovement jump (CMJ) variables was assessed for convergent validity. Intraclass correlation coefficient (ICC) and coefficient of variation (CV) were calculated for reliability analyses, and convergent validity was assessed with Spearman's correlation coefficient (ρ). In the dominant leg, single-leg performance parameters showed moderate-to-excellent intraday reliability (ICC = 0.65-0.90, CV = 4.3-11.2%) and moderate interday reliability (ICC = 0.54-0.74, CV = 5.8-13.5%). In the nondominant leg, all single-leg STS performance parameters showed good intraday (ICC = 0.79-0.86, CV = 3.8-9.8%) and interday reliability (ICC = 0.75-0.82, CV = 4.6-9.7%). STS times in the dominant and nondominant legs were inversely related to unilateral CMJ velocity (ρ = -0.47 and -0.38, respectively). CoP sway velocity in the nondominant leg showed positive correlations with unilateral CMJ power and velocity (ρ = 0.38 and 0.54, respectively). In conclusion, the force plate-based single-leg STS test provides reliable measures of STS time, GRF, and CoP sway velocity in trained adults and could be used to assess lower-limb function and asymmetry.es
dc.description.disciplineTerapia y Rehabilitaciónes
dc.identifier.citationMakaracı Y, Nas K, Ruiz-Cárdenas JD, Gündüz K, Aydemir M, Orange ST. Test-Retest Reliability and Convergent Validity of Piezoelectric Force Plate Measures of Single-Leg Sit-to-Stand Performance in Trained Adults. J Strength Cond Res. 2023;37(12):2373-80.es
dc.identifier.issn1064-8011
dc.identifier.urihttp://hdl.handle.net/10952/8059
dc.issue.number12es
dc.journal.titleJournal of Strength and Conditioning Researches
dc.language.isoenes
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.accessRightsopen accesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectSingle leges
dc.subjectForce platees
dc.subjectAthleteses
dc.subjectInjuryes
dc.subjectTrainedes
dc.subjectValidityes
dc.titleTest-Retest Reliability and Convergent Validity of Piezoelectric Force Plate Measures of Single-Leg Sit-to-Stand Performance in Trained Adultses
dc.typejournal articlees
dc.volume.number37es
dspace.entity.typePublication
person.affiliation.nameUniversidad Católica San Antonio de Murcia
person.identifier.orcid0000-0002-8882-4965
relation.isAuthorOfPublicationfe31a452-0ea2-4f8c-ab64-eb5b189ed111
relation.isAuthorOfPublication.latestForDiscoveryfe31a452-0ea2-4f8c-ab64-eb5b189ed111

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2023_Makaraci_Test-retest reliability single-leg STS forceplate_accepted.version.pdf
Size:
720.14 KB
Format:
Adobe Portable Document Format
Description:

Collections