Abstract

Objective: The purpose of the present study was to compare the insertion torque and implant stability quotient between different drill design for implant site preparation. Materials and Methods: Synthetic blocks of bone (type I density) were used for drilling procedures. Three groups were evaluated: Group G1 - drilling with a single bur for a 4.2 mm conical implant; Group G2 and Group G3 - drilling with three consecutive burs for a 4.1 mm cylindrical implant and for a 4.3 mm conical implant respectively. For each group, 15 drilling procedures were performed without irrigation for 10-mm in-depth. The drilled hole quality (HQ) after the osteotomy for implant site preparation was measured in the five-first holes through a fully automated roundness/cylindricity instrument at three levels (top, middle, and bottom of the site). The insertion torque value (ITV) was achieved with a computed torquimeter and the implant stability quotient (ISQ) values were measured using a resonance frequency apparatus. Results: Thesingledrill(group1)achievedasignificantlyhigherITVandISQthanthemultipledrills for osteotomy (groups 2 and 3). Group 1 and 3 displayed significantly better HQ than group 2. Conclusions: Within the limitations of the study, the results suggest that the hole quality, in addition to the insertion torque, may significantly affect implant primary stability.

Description

This is the peer reviewed version of the following article: Gehrke SA, Guirado JLC, Bettach R, Fabbro MD, Martınez CP-A, Shibli JA. Evaluation of the insertion torque, implant stability quotient and drilled hole quality for different drill design: an in vitro Investigation. Clin. Oral Impl. Res. 00, 2016, 1–7], which has been published in final form at 10.1111/clr.12808. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Use of Self-Archived Versions.

Disciplines

Bibliographic citation

Collections

Endorsement

Review

Supplemented By

Referenced By

Creative Commons license

Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivatives 4.0 Internacional