Abstract
Objective. To analyze and compare measurements of spine kinematics during prehospital emergency responders’
placement of a patient on a spinal backboard or a scoop stretcher.
Methods. Cross sectional, quasi-experimental clinical simulation to compare misalignment (main endpoint) by means
of data from a 3-dimensional motion capture system.
Results. Mean (SD) misalignment during placement on the 2 devices was 37.53° (14.15°). By device, mean misalignment
was 31.08° (6.38°) for the scoop stretcher and 43.97° (7.97°) for the backboard (P=.048).
Conclusion. Less misalignment occurs during placement on the scoop stretcher than on the spinal backboard.
Description
Disciplines
Type
Bibliographic citation
Gordillo, R. M., Alcaraz, P. R., Manzano, F. C., Freitas, T. T., Marín-Cascales, E., Juguera, L. R., & Pardo, M. R. (2017). Kinematic analysis of the spine during placement on 2 transfer devices: a spinal backboard and a scoop stretcher. Emergencias: revista de la Sociedad Espanola de Medicina de Emergencias, 29(1), 43-45.