Mostrar el registro sencillo del ítem

dc.contributor.authorWiorek, Alexander
dc.contributor.authorHussain, Ghulam
dc.contributor.authorMolina Osorio, Andres F.
dc.contributor.authorCuartero, Maria
dc.date.accessioned2024-02-08T11:35:13Z
dc.date.available2024-02-08T11:35:13Z
dc.date.issued2021
dc.identifier.urihttp://hdl.handle.net/10952/7281
dc.description.abstractHerein, we report on a reagentless electroanalytical methodology for automatized acid−base titrations of water samples that are confined into very thin spatial domains. The concept is based on the recent discovery from our group (Wiorek, A. et al. Anal. Chem. 2019, 91, 14951−14959), in which polyaniline (PANI) films were found to be an excellent material to release a massive charge of protons in a short time, achieving hence the efficient (and controlled) acidification of a sample. We now demonstrate and validate the analytical usefulness of this approach with samples collected from the Baltic Sea: the titration protocol indeed acts as an alkalinity sensor via the calculation of the proton charge needed to reach pH 4.0 in the sample, as per the formal definition of the alkalinity parameter. In essence, the alkalinity sensor is based on the linear relationship found between the released charge from the PANI film and the bicarbonate concentration in the sample (i.e., the way to express alkalinity measurements). The observed alkalinity in the samples presented a good agreement with the values obtained by manual (classical) acid−base titrations (discrepancies <10%). Some crucial advantages of the new methodology are that titrations are completed in less than 1 min (end point), the PANI film can be reused at least 74 times over a 2 week period (<5% of decrease in the released charge), and the utility of the PANI film to even more decrease the final pH of the sample (pH ∼2) toward applications different from alkalinity detection. Furthermore, the acidification can be accomplished in a discrete or continuous mode depending on the application demands. The new methodology is expected to impact the future digitalization of in situ acid−base titrations to obtain high-resolution data on alkalinity in water resources.es
dc.language.isoenes
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.titleReagentless Acid−Base Titration for Alkalinity Detection in Seawateres
dc.typearticlees
dc.rights.accessRightsopenAccesses
dc.journal.titleAnalytical Chemistryes
dc.volume.number93es
dc.description.disciplineFarmaciaes
dc.identifier.doihttps://doi.org/10.1021/acs.analchem.1c02545es


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como Attribution-NonCommercial-NoDerivatives 4.0 Internacional