Mostrar el registro sencillo del ítem

dc.contributor.authorGómez Morte, Teresa
dc.contributor.authorGómez López, V. M.
dc.contributor.authorLucas Abellán, Carmen
dc.contributor.authorMartínez Alcaraz, I
dc.contributor.authorAyuso, A.
dc.contributor.authorMartínez López, S
dc.contributor.authorPérez, S.
dc.contributor.authorBarceló, D.
dc.contributor.authorFini, P.
dc.contributor.authorCosma, P.
dc.contributor.authorCerón Carrasco, Jose Pedro
dc.contributor.authorFortea, María Isabel
dc.contributor.authorNúñez Delicado, Estrella
dc.contributor.authorGabaldón, José Antonio
dc.date.accessioned2024-07-18T07:44:32Z
dc.date.available2024-07-18T07:44:32Z
dc.date.issued2020-07-16
dc.identifier.citationT. Gómez-Morte, V.M. Gómez-López, C. Lucas-Abellán, I. Martínez-Alcalá, M. Ayuso, S. Martínez-López, N. Montemurro, S. Pérez, D. Barceló, P. Fini, P. Cosma, J.P. Cerón-Carrasco, M.I. Fortea, E. Núñez-Delicado, J.A. Gabaldón, Removal and toxicity evaluation of a diverse group of drugs from water by a cyclodextrin polymer/pulsed light system, Journal of Hazardous Materials, Volume 402, 2021, 123504,ISSN 0304-3894, https://doi.org/10.1016/j.jhazmat.2020.123504.es
dc.identifier.urihttp://hdl.handle.net/10952/8013
dc.description.abstractThe presence of pharmaceutical compounds (PhCs) in the effluents of wastewater treatment plants (WWTPs) is an ecological concern. The issue could be alleviated by trapping those substances by cyclodextrin (CD) polymers or photolyzing them by pulsed light (PL). Consequently, a sequential CD polymer/PL system was tested for the removal of PhCs. Firstly, a survey detected the presence of recurrent PhCs in the effluents of local WWTPs. Then, pure water was spiked with 21 PhCs, 100 μg/L each one. The three-dimensional network provides amphiphilic features to the CD polymer that reduced the pollutant concentration by 77 %. Sorption involves a plead of physical and chemical mechanisms hindering the establishment of a general removal model for all compounds. The performed simulations hint that the retention capacity mainly correlates with the computed binding energies, so that theoretical models are revealed as valuable tools for further improvements. The complementary action of PL rose the elimination to 91 %. The polymer can be reused at least 10 times for ibuprofen (model compound) removal, and was able to eliminate the ecotoxicity of an ibuprofen solution. Therefore, this novel sequential CD polymer/PL process seems to be an efficient alternative to eliminate PhCs from wastewater.es
dc.language.isoenes
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectEmerging pollutantses
dc.subjectCyclodextrines
dc.subjectPulsed lightes
dc.subjectWastewater treatmentes
dc.subjectEnvironmental contaminationes
dc.titleRemoval and toxicity evaluation of a diverse group of drugs from water by a cyclodextrin polymer/pulsed light systemes
dc.typearticlees
dc.rights.accessRightsopenAccesses
dc.journal.titleJournal of Hazardous Materialses
dc.volume.number402es
dc.issue.number123504es
dc.description.disciplineCiencias Ambientaleses
dc.identifier.doihttps://doi.org/10.1016/j.jhazmat.2020.123504es


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como Attribution-NonCommercial-NoDerivatives 4.0 Internacional